Products Dispensers - Bunch 5634

Eagle Bunch Dispenser

Information

NCR 5634 Bunch Dispenser
  • Up to 50 bills presented in a single Bunch per transaction
  • Up to 4 denominations using Front and Rear Access
  • Uses NCR Standard Cassette (2700 notes each) - Shipped 3 million worldwide
  • NCR Tamper Indicating or NCR Lockable Currency Cassettes available
  • Note security (Bills retracted into purge bin if not taken)
  • Purge Bin Options (Open / Lockable)
  • Accurate bill sensing technology
  • Designed for 10,000 trans/ month
  • Standard RS232 Interface
  • Active Note marking
  • Euro Compatible

Workload

Hours per day= 24
Average number of transactions per day= 280
Average number of items dispensed per transaction= 2.5
Average Workload= 255,500 Items/year

Physical Dimensions

Weight:
Basic Unit (4 high) with empty media containers= 46 kg
Currency Cassette empty= 3.2 kg
Currency Cassette full= 6.0 kg
Reject Bin empty= 0.37 kg
Reject Bin full= 0.41 kg

Space Dimensions:
Width (with feet mounting)= 300mm (330mm)
Height 1H and 4H= 310mm and 720mm *
Depth= 475mm *

* EXCLUDING ANY INTERFACING WITH ATM REQUIREMENTS

Standard Currency

The pick modules are capable of dispensing new or used currency. Certain non-currency media having similar material and dimensional characteristics as currency may be dispensed.
  • Standard Currency Size Range:
    • Width
      • min 65mm
      • max 95mm
    • Length
      • min 120mm
      • max 178mm

  • Tolerance on bill dimensions width and length +/- 2mm
  • Thickness
    • min 0.06mm
    • max 0.26mm

Power Requirements

+5 V +/- 5% 1.5 A
+24 V +/- 10% 2.0 A
115V AC 5.5A RMS 20.0 amps surge or
230V AC 3.0A RMS 10.0 amps surge.

Normal Operating Range

Temperature, Dry Bulb 10ºC to 50ºC *
Temperature Change 10ºC per hour max.
Relative Humidity Change 20% to 80%, 10% per hour max, no condensation
Maximum Due Point Temperature 26ºC

* Note:The module top end temperature is elevated by 10°C above the Range 3 limit to reflect the conditions inside the security enclosure.

Extreme Power-On Range

Temperature, Dry Bulb 0ºC to 55ºC
Temperature Change 10ºC per hour max.
Relative Humidity Range 10% to 95%
Change 10% per hour max, no condensation

Security

Three levels of Security are available in respect to physical security of the media:
  • Standard
  • Tamper indicating with mechanical devices
  • Lockable

Contact NCR OEM for more detailed product specifications.